What maintenance is required for the Ingersoll Rand 18002386 Bare Pump?
Regularly check the pump's cylinder, valves, and gaskets for wear, scoring, or leaks to maintain proper compression. Change crankcase oil according to runtime hours and ensure proper lubrication of bearings. Clean cooling fins and remove debris around the intake to prevent overheating. Tighten mounting bolts and inspect drive belts for proper tension to reduce vibration.
What are common issues with the Ingersoll Rand 18002386 Bare Pump?
Pump fails to build pressure.
Cylinder leaks air.
Bearings damage under load.
Pump vibrates excessively.
Please, mind that only logged in users can submit questions
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Installation Steps
Step1: Ensure the air compressor is disconnected from power and drained of air.
Step2: Remove the old pump by loosening mounting bolts.
Step3: Clean the mounting surface and check for debris.
Step4: Position the new bare pump in place.
Step5: Secure it with mounting bolts, tightening evenly.
Step6: Reconnect all fittings and hoses.
Step7: Test the compressor for proper operation and leaks.